ENERGY SAVING IN COMPRESSOR DEVICES IN WASTEWATER TREATMENT FACILITIES

Авторы

  • Maxmudov M. I. Автор
  • Koziyev Z. E. Автор
  • Temirov L.A. Автор

DOI:

https://doi.org/10.5281/zenodo.4763231

Ключевые слова:

Wastewater, specific oxygen consumption, water solubility of air oxygen, compressor, induction motor, frequency, power, efficiency, power factor, energy saving.

Аннотация

The article discusses the issues of energy saving of compressor units of treatment facilities. The main parameters of the aeration system compressor were calculated by determining the flow rate, temperature, and dissolved oxygen concentration of wastewater in the aeration tank. The possibilities of energy saving by changing the frequency of an induction motor are determined depending on the load on the device. The results of the study are presented in the form of tables and graphs.

Опубликован

2021-05-14

Как цитировать

I., M. M., E., K. Z., & L.A., T. (2021). ENERGY SAVING IN COMPRESSOR DEVICES IN WASTEWATER TREATMENT FACILITIES. Евразийский журнал академических исследований, 1(2), 236-241. https://doi.org/10.5281/zenodo.4763231
Innovative Academy RSC
Article metrics Views and PDF downloads
0 Views
0 Downloads